Simulation variables: Grid system

<< Click to Display Table of Contents >>

Navigation:  Project design > Results >

Simulation variables: Grid system

Previous pageReturn to chapter overviewNext page

The following variables are calculated during the simulation process, and available as results:

Meteo and irradiation variables: see previous page.

PV array  behavior

PNomArray

Nominal Installed Power

( = Nb. PV modules * nameplate PNom)



EArrRef

Array reference energy for PR calculation                                    
(as defined in the IEC EN 61724 norm)

=  GlobInc * PNomArray



EArrNom

Array nominal energy at STC, according to the one-diode model
Starting point of the array energy evaluation in the loss diagram

=  GlobEff * Pmpp (STC)



GIncLoss

PV loss due to irradiance level

(low-light efficiency)



TempLoss

PV loss due to temperature

(see Uc and UV parameters)



SpctCor

Spectral correction

(amorphous modules, CdTe, Sandia model)



LigSoak

Light soaking for CIS/CIGS modules




ShdElec

Electrical loss for mismatch due to shadings

(calculation "according to module strings" or "ModuleLayout")



ModQual

Module quality loss

(users choice concerning real performance of the modules)



LIDLoss

Light Induced degradation

(for mono-crystalline modules, p-type wafer only)



MisLoss

Module array mismatch loss




OhmLoss

Ohmic wiring loss in the DC array




EArrMPP

Array MPP energy after all array losses

(on the loss diagram)



EArray

Effective energy at the array output

(taking inverter operating point displacements into account - not represented on the Loss diagram)



Iarray

Array current

(taking inverter operating point displacements into account)



Uarray

Array voltage

(taking inverter operating point displacements into account)



 

Inverter behavior   (see also Inverter operating limits)

InvLoss

Global inverter loss


IL_Oper

Inverter Loss during operation

(efficiency curve)

IL_Pmin

Inverter Loss due to power threshold


IL_Pmax

Inverter Loss due to power overload


IL_Vmin

Inverter Loss due to low voltage MPP window


IL_Vmax

Inverter Loss due to upper voltage MPP window


IL_Night

Inverter night energy

(usually negligible or null)

Syst_ON

System operating duration


EOutInv

Available Energy at Inverter Output


 

Energy output and use

Aux_Lss

Auxiliaries consumption

(Fans, other... )

EacOhmL

AC ohmic loss

(wiring up to injection point)

ETrfLss

External transfo loss

(iron loss and ohmic contribution)

UnavLss

System Unavailability loss

Specified or random periods of shutdown

E_Solar

Energy supplied to the user from solar

if load is defined (Netmetering)

E_User

Energy need of the user

if load is defined (Netmetering)

E_Avail

Energy available  from the sun

= EOutInv - losses after inverter (Wiring, night losses)

E_Grid

Energy injected into the grid


EApGrid

Apparent energy into the grid

when Power factor defined

ERegrid

Reactive energy into grid

when Power factor defined

SolFrac

Solar fraction

ESolar / EUser

 

Efficiencies

EffArrR

Array Efficiency

EArray / rough area

EffArrC

Array Efficiency

EArray / cells area (=0 when cells area not defined)

EffSyR

System efficiency

EOutInv / rough area

EffSyC

System efficiency

EOutInv / cells area.

EffInvB

Inverter efficiency

Threshold loss included

EffInvR

Inverter efficiency

When operating

 

Normalised performance index (cf IEC EN 61724, usually expressed and plotted as values per day)

Yr  or

Reference Incident Energy in collector plane

= GlobInc  [kWh/m²] (kWh irradiance)

Yr

Normalized Reference nominal energy at STC

= EArrRef / PNomArray  [kWh/kWp] (kWh electrical)

Ya

Normalized Array Production

= EArray / PNomArray [kWh/kWp]

Yf

Normalized System Production

= EGrid or EAvail / PNomArray [kWh/kWp]

Lc

Normalized Array Losses

= Yr - Ya

Ls

Normalized System Losses

= Ya - Yf

PR

Performance Ratio

= Yf / Yr   =   E_Grid  / (GlobInc * PNomArray)

 

NB: The Normalized Reference nominal energy at STC  Yr [kWhel/kWp] is the electrical energy which would be produced by the Reference incident energy on the collector plane under STC conditions (1 kWirrad/m2, 25°C). This explains that the values are identical.