Open Circuit Voltage

<< Click to Display Table of Contents >>

Navigation:  Physical models used > Batteries - General model description > Lithium-ion voltage model >

Open Circuit Voltage

Previous pageReturn to chapter overviewNext page

(go directly to the help section of the form, "Lithium-ion : Open Circuit Voltage")

 

The basic model takes the following form :

 

OCV(SOC)  =   Eo +  Alpha . (SOC - 0.5) - K / SOC

 

with:

OCV =

Open Circuit Voltage

Eo  =

base voltage

Alpha =

slope of the open-circuit line

SOC =

state of  charge (varies from 0 to 1)

K =

SOC correction factor

 